Installing and Controlling Third-Party 
 Devices
 Waters 996 and 2996 PDA Detectors: Installation
 
 Waters 996 and 2996 PDA Detectors: Installation
| Device Type: | |
| Device Driver: | Waters: 996/2996PDA | 
| Hardware 
		 Options | Required Firmware version: 2.3. Detectors equipped with previous firmware versions are updated automatically upon connect with Chromeleon. | 
| Restrictions: | 
 | 
What is required?
| Licenses: | Timebase 
		 Class 2 | 
| Connection: | The following cable is required: GPIB cable (Thermo Scientific/Dionex 
		 part no.: 5919.0013; for more information refer to  
 You cannot connect the Waters 996 and 2996 PDA Detectors to a UCI Universal Chromatography Interface because the UCI does not provide a GPIB connector. | 
| Hardware | GPIB interface card or GPIB/USB adapter 
 
 | 
| Software | VISA library (≤ version 14.0) | 
| Waters2690_996.pan | 
Hardware Installation
First, install Chromeleon software, and then connect the instrument using the GPIB IEEE 488 bus cable from Dionex.
Follow the description in the instrument's manual to set the GPIB number on the instrument's rear panel, using the Dip switches. Make sure that the new GPIB address has not yet been assigned to another instrument.
 Notes:
 Notes:
When using a Waters 996 PDA detector with an Alliance HPLC system, make sure that:
Only one (1) Alliance HPLC system per GPIB interface card (GPIB bus) is allowed. If more than one Alliance system should be connected, a separate GPIB card for each system is required on the computer. Alternatively, you can use two separate USB GPIB adapters. Do not mix GPIB cards from different manufacturers. When using USB GPIB adapters, use adapters of the same type.
Make sure that only one (1) Waters 996 PDA detector is connected per Alliance system and GPIB bus.
When connecting several devices or systems via GPIB, connect them in series (not in a star structure) and turn all devices on. Otherwise, communication problems may occur.
Software Installation
For details about how to add timebases and 
 device drivers to the Server Configuration, refer to  Adding, Configuring or Deleting Devices. 
 When you add a driver to the timebase, the configuration dialog or wizard 
 opens automatically. For information about the settings, click the Help button on a page or press F1.
 
 Adding, Configuring or Deleting Devices. 
 When you add a driver to the timebase, the configuration dialog or wizard 
 opens automatically. For information about the settings, click the Help button on a page or press F1.
Troubleshooting
 Waters Instruments: Troubleshooting
 Waters Instruments: Troubleshooting
 GPIB-Connected Devices: Troubleshooting
 GPIB-Connected Devices: Troubleshooting
For a list of all error messages, refer to the Error Levels tab page of the instrument's Properties in the Chromeleon Server Configuration program.
Further Information
For more installation details, please refer to the manual for the instrument.
For information about the supported GPIB interfaces, 
 refer to  Connecting Third-Party Devices via GPIB.
 
 Connecting Third-Party Devices via GPIB.
For an overview of the different Waters instruments 
 that can be controlled by Chromeleon, refer to  Waters.
 Waters.